Question 1
Is this guaranteed that the U voltage range from 33V - 120V
for NT1 and 42V-120V for NT+2ab? Answer
Yes, it is guaranteed.
Question 2
What is the minimum power required by NT+2ab from exchange
to work in Restricted Mode?
Answer
Minimum Power required by NT+2ab+USB to work fine in ab-Auto
Restricted Mode is 1700 mW. The unit will work fine with the
exchange which is able to provide at least 1700 mW.
Question 3
In which Mode the programming of features is possible in NT+2ab?
Answer
All programming of features can be done in any mode i.e. Normal
or Restricted. During programming in Restricted Mode ab port
should be configured.
Question 4
How long does the setting inside the NT+2ab that are programmed
from the analog phone will last?
Answer
The setting will last forever unless changed by the user.
Question 5
What happen if user skipped the subscription of MSN number
to each analog port, but proceed to set the MSN for identification?
Answer
If user skipped the subscription of MSN number, but proceed
to set the MSN for identification. Then by default always
Main line number will be set as MSN for Identification.
Question 6
In MSN for Identification, what is the first setting mean
(Y890#)?
Answer
For this feature user configurable "CLIR enable / disable
facility" through functional code, should be present
on the ISDN Line. It will restrict the number i.e. when user
select this, no number will be present to the called party
during an outgoing call from that port.
Question 7
Why the call forwarding functionality is not working on the
MSN numbers, while it is working on the main number?
Answer
The Call Forwarding facility on the MSN's number will also
work when the Exchange provides it on all MSN’s number
also.
Question 8
How Internal Call can be make, and will it be charged?
Answer
When both of the analog ports are connected with analog phone,
users will be able to perform internal call (like intercom)
from one to another by pressing *00*. This call will not be
charged.
Question 9
How far can an analog phone be from the ab port (the cable
length)?
Answer
It depends upon the impedance of analog phone as well as the
cable connected between analog phone and ab – port.
The total impedance should not be greater than 600 Ohm.
Question 10
Is all the features of NT+2ab+USB is provided by Exchange?
Answer
Some of the features of the NT+2ab+USB requires services offered
by the exchange, thus, users have to subscribe the services
first to enable it. For example, call waiting, call hold,
call forwarding etc.
Question 11
How do I program numbers into the digital ports on the NT+2ab?
Answer
The programming is done on the customer's equipment. The MSN
number is programmed into an ISDN telephone or on the PC controlling
the ISDN modem.
|